ALERT!

This site is not optimized for Internet Explorer 8 (or older).

Please upgrade to a newer version of Internet Explorer or use an alternate browser such as Chrome or Firefox.

Robotic Sleeve Lobectomy of the Right Lower Lobe

Tuesday, June 20, 2017

Jayakumar, Shruti; Nardini, Marco; Dunning, Joel (2017): Robotic Sleeve Lobectomy of the Right Lower Lobe.
CTSNet, Inc.. https://doi.org/10.25373/ctsnet.5104894.v1
Retrieved: 19:41, Jun 20, 2017 (GMT)

This is the case of 65-year-old male with a proven adenocarcinoma at the orifice of the apical segment of the right lower lobe. He underwent a robotic sleeve lobectomy with a station 7 lymphadenectomy. The right lower lobe artery and right lower lobe vein were divided using the Covidien Curved Tip Stapler with a leader catheter, which facilitated ease of stapling by the assistant. Initially, the right lower lobe bronchus was cut with scissors and the orifice was stitched. After a frozen section of the bronchus was identified as positive for malignancy, the margins were extended and a sleeve resection was carried out. The middle lobe bronchus and bronchus intermedius were anastomosed using continuous, 4.0 barbed (V-Loc) sutures. Following a slight air leak, a few more sutures were added to the anastomosis, which resolved the leak.

Add comment

Log in or register to post comments