ALERT!

This site is not optimized for Internet Explorer 8 (or older).

Please upgrade to a newer version of Internet Explorer or use an alternate browser such as Chrome or Firefox.

Aortic Valve Replacement and Ascending Aortic Replacement Through an 8 cm Ministernotomy 

Monday, April 21, 2025

Gaudiani V, Tsau P. Aortic Valve Replacement and Ascending Aortic Replacement Through an 8 cm Ministernotomy. April 2025. doi:10.25373/ctsnet.28832411

This case features a 58-year-old male with a dilated aorta and sever aortic regurgitation.  The procedure began with an incision through the manubrium and upper sternum extending to the third intercostal space, followed by a T-shaped incision. The pericardium was carefully tucked under the retractor, bringing the aorta up using an Estech retractor.   

A high aortic cannulation was placed, and a stylet was inserted into the aortic canula without requiring hand placement within the ministernotomy. Retrograde cardioplegia cannula was placed and femoral venous cannulation was performed. The aorta was opened, and the dilated aorta was excised.   

The aortic valve leaflets were removed, and the horizontal mattress sutures were placed, followed by the placement of the 29 mm Mosaic valve.  After this, a Dacron graft was placed to the proximal and distal aorta.  


Disclaimer

The information and views presented on CTSNet.org represent the views of the authors and contributors of the material and not of CTSNet. Please review our full disclaimer page here.

Add comment