Changes in end organ function were assessed in 59 pts having a continuous flow LVAD in place for more than 3 years. Renal and hepatic function improved initially, but renal function deteriorated to preoperative levels during the follow-up period.
ALERT!
This site is not optimized for Internet Explorer 8 (or older).
Please upgrade to a newer version of Internet Explorer or use an alternate browser such as Chrome or Firefox.
Cardiac
March 5, 2017
March 5, 2017
The authors describe a 10-year experience with extended arteriotomy for endarterectomy of a diffusely diseased LAD, using an internal mammary artery for reconstruction. Perioperative mortality was 1.1% and postoperative MI occurred in 9%. Survival at 5 years was 89% and freedom from acute cardiovascular events was 74%.
March 5, 2017
This trial randomly assigned 4,752 patients from 19 countries to either on-pump or off-pump CABG with a mean follow-up of 4.8 years. The authors report no difference in death, stroke, myocardial infarction, renal failure or repeat revascularization at 5 years between the two groups.
March 2, 2017
William Brawn discusses his approach to hypoplastic left heart syndrome.
March 1, 2017
John Pepper of the Royal Brompton and Harefield Hospitals, London, United Kingdom, argues that there is not yet the evidence to support the superiority of minimally invasive aortic valve replacement over a full sternotomy approach.
February 27, 2017
This video demonstrates a technique for performing aortic and mitral valve replacements simultaneously through a partial sternotomy with an excellent exposure of the corresponding anatomical structures.
February 26, 2017
In this manuscript, the authors describe their findings in an observational prospective study of 52 patients who had tentative diagnoses of bioprosthetic valve thrombosis (BPVT) of surgically implanted valves over a 3-year period.
February 24, 2017
In a discussion filmed at the 2016 EACTS Annual Meeting in Barcelona, Spain, a group of experts consider how CT Surgery allied health professionals can create an evidence-based practice.
February 23, 2017
Christopher Young of St. Thomas' Hospital, London, UK, reviews the evidence for minimally invasive aortic valve replacement.
February 23, 2017
Coronary and/or CT angiograms were performed on 585 of 762 (94%) patients at varying intervals after CABG using the PAS-Port System proximal anastomotic device. The authors retrospectively evaluated the SVG patency at a mean follow-up interval (between CABG and the diagnostic procedures) was 319 ± 624 days.