ALERT!

This site is not optimized for Internet Explorer 8 (or older).

Please upgrade to a newer version of Internet Explorer or use an alternate browser such as Chrome or Firefox.

Lower versus Higher Hemoglobin Threshold for Transfusion in Septic Shock

Thursday, October 9, 2014

Submitted by

Source

Source Name: New England Journal of Medicine

Author(s)

LB Holst and others for the TRISS Trial Group and the Scandinavian Critical Care Trials Group

This randomized trial investigated two different thresholds for triggering transfusion in patients with septic shock: 9 g/dL or 7 g/dL.  The lower threshold group received a median of 1 unit of blood compared to 4 in the higher threshold group.  90 day mortality rates and other morbidity were similar between the groups.  